Today
Every rail project asks for fire safety proof to EN 45545-2 for each component in the vehicle. The requirement set depends on where the part is installed, the limit values on the hazard level HL1 to HL3, which follows from how the vehicle is operated and how it is built. A seat cover needs different tests than a curtain or a floor covering, and each test report covers only the construction that was tested. Today the quality team builds the matrix of article, requirement and test report by hand for every enquiry, from folders full of reports, some still to the old DIN 5510-2. A missing proof often shows up only when the vehicle maker reviews the documents, and a new fire test takes weeks.
An example
A seat maker asks Fibrana for seat cover fabric, curtain fabric and a needle-felt floor covering for a regional multiple unit (HL2) and for night trains with sleeping cars (HL3), 14 articles with colour variants in all. The agent assigns R21 to the seat covers, R1 to the curtains and R10 to the floor covering and checks 38 reports from the DMS. Everything is covered for HL2. For HL3 the measured smoke density of the seat cover is not good enough, and the report for the curtain fabric is still to DIN 5510-2. The floor covering was tested for HL3, but with a different backing. The head of quality orders new lab tests for the curtain fabric and the floor covering, passes the seat cover for HL3 to development and sends the customer the matrix with the existing reports in the same week.
Your data, wherever it lives
Today the proof sits in folders full of fire test reports as PDFs or scans, some still to DIN 5510-2, article data and recipes in PLM and ERP, and customers' requirement lists as spreadsheets in e-mails. demi reads, understands and links them per article and vehicle project, with your access rights. The evidence matrix for a new enquiry is then ready in hours instead of days, and your quality team decides what goes to the customer.
Where the data lives today
- PDFs
- Scans & paper
- Office files
- E-mails
- PLM
- ERP
- DMS & archive
How demi solves it
Three layers in this order: connect the data first, then the rights, then the AI.
- 1 · ConnectData Layer
Data sources in this case: PLM, ERP, DMS, customers' requirement lists and test reports as PDFs or scans. demi replaces nothing and links, per article, construction, finish, weight per square metre and colour variants to every fire test report: lab, date, standard, requirement set, hazard level and measured values. Every customer enquiry then shows which articles are covered and which are not.
- 2 · PermitPermission Layer
Test reports are visible to quality, development and rail sales; the recipes of the flame-retardant finish only to development and quality. Only the head of quality releases which proofs go to the customer; every release is recorded with name and date.
- 3 · ActIntelligence Layer
The agent reads standard, test method, requirement set, hazard level and measured values from every report, old scans included. The mapping from installation location to requirement set and the limits per hazard level are stored as fixed, versioned rules; the check follows these rules, and the language model only explains why a report falls short. It shows each gap with its reason, such as a missing smoke density value, a report for a different construction or a report to DIN 5510-2.
How it runs
- 1
The enquiry from the vehicle or seat maker arrives with an article list, installation locations and hazard level, as a spreadsheet or PDF.
- 2
The agent assigns each article its product category and requirement set by location, such as R21 for seat covers, R1 for curtains and R10 for floor coverings.
- 3
It checks every existing fire test report against requirement set, limit values and tested construction.
- 4
The result is the evidence matrix: covered, covered with restrictions or open, each line naming the report it comes from.
- 5
Quality decides on new tests at the lab and releases the matrix with the reports for the customer.
What changes
One evidence matrix per rail project, each line with its test report
Missing tests show up at the enquiry, not at acceptance
Existing test reports carry over into new projects
What does it bring you?
Check it with your own numbers
Every starting value is an assumption you can change. The calculation sits right below, step by step.
Your numbers
Result
+230 hfreed per year
Assumptions and calculation
demi gives each article its requirement and test report and shows the gaps; your quality team decides.
8 h → 4.8 h per case
How we calculate
6 evidence matrices × 8 h × 40% × 1.0 (manual) × 12 months = 230 h
Value per year, before demi costs
Freed per year+230 h
Assumption: labour cost of €49.50 per hour in German manufacturing in 2025 (Destatis), plus workplace, IT and overheads.
= Value per year, before demi costs
+€14,950
gained per year
230 h ÷ 1,760 h per role = 0.1 full-time roles
An estimate, not a promise. The starting values are assumptions for an industrial company with 150 to 500 people.
Combine with more cases and get the packageQuestions about this use case
How does demi know which requirement set applies to a component?
From the table of product categories in EN 45545-2, which your quality team stores as a rule, and from the installation location the customer states. For components not listed in any category, the agent shows the rules for non-listed products and marks the assignment for review. Your quality team decides, and the decision then applies to every later project.
Does a test report also cover a new colour or finish?
Not automatically. A report proves the construction that was tested: fibre, weight per square metre, finish, coating and, for seat covers, the upholstery it was tested on. demi shows per article how it differs from the tested sample. Whether the report still holds or a new test is needed is your call, with the test lab if necessary.
What about old test reports to DIN 5510-2?
The agent reads them too and labels them as proof to the old standard. For a project to EN 45545-2 they are usually not enough, but they show how an article has behaved in fire tests so far. That lets you plan new tests where they are needed instead of for the whole range.
Can demi compile fire safety proof for other markets too?
Yes, once your quality team stores their rules, such as NFPA 130 for North America or the requirements of individual operators. The agent then checks your reports against each set of rules and shows which test serves several markets at once.