Today
Food machinery must be easy to clean: no dead spaces, no narrow crevices, rounded internal corners, smooth surfaces and surfaces that water runs off. Today this is checked by eye on the model, under deadline pressure and by the few who know the rules. What slips through is found in the customer's hygiene audit or the first cleaning test, and then a finished machine has to be reworked.
An example
Ebert & Lorenz Maschinenbau is designing a special machine that fills deli salads into cups. Before release demi checks the 186 parts in the food and splash zones and reports 15 spots: three internal corners in the dosing hopper with 1 mm instead of at least 3 mm radius, a 0.4 mm gap between hopper and mounting plate, two socket head screws right above the open cup, a horizontal cover where cleaning water stays, and eight sheet-metal parts without a surface callout. The engineer rounds the corners, welds the plate along its full length, fits hygienic screws, tilts the cover and adds the surface callouts before a single part is made.
Your data, wherever it lives
Today the basis is scattered: 3D models in the CAD system, parts, revisions and materials in the PLM, drawings with surface callouts as PDFs, standards and your own hygiene guideline in the DMS, the customer's requirements in e-mails. demi reads and understands all of it and links it per part and zone, with your access rights. The AI then checks an assembly in minutes for dead spaces, radii and crevices, and your engineer decides on every change.
Where the data lives today
- CAD & drawings
- PLM
- PDFs
- DMS & archive
- E-mails
How demi solves it
Three layers in this order: connect the data first, then the rights, then the AI.
- 1 · ConnectData Layer
Data sources in this case: CAD, PLM, drawings as PDFs, the DMS with standards and your hygiene guideline, and the customer's requirements from e-mails. demi replaces nothing and links every part in the 3D model to its zone, its material, the surface callout on the drawing and the rule that applies in that zone.
- 2 · PermitPermission Layer
Models and customer requirements are visible to engineering, project management and quality on the project. The responsible engineer assesses the findings, and only the authorized person releases in the PLM; every accepted or rejected finding is recorded with its reason.
- 3 · ActIntelligence Layer
Radii, gap widths, slopes and dead-space lengths are measured by a fixed geometry check on the model, with the limits you set per zone. The agent adds surface, weld and material callouts from the drawing and explains each finding with location, measured value and rule. The language model explains and suggests solutions from earlier designs; it never measures.
How it runs
- 1
The engineer submits the assembly for a hygiene check; the zones are marked in the model by color or attribute.
- 2
The geometry check measures internal radii, crevices, blind holes, exposed threads, slopes and dead spaces.
- 3
The agent compares surface, weld and material callouts on the drawings with the rules per zone.
- 4
Each finding comes with its view in the model, measured value, rule and a solution from earlier designs.
- 5
The engineer changes or justifies each spot, then the authorized person releases the assembly with its check report in the PLM.
What changes
Hygiene weak spots found in the model, not at the customer
Less rework on finished machines
One check report per assembly for audits and the technical file
What does it bring you?
Check it with your own numbers
Every starting value is an assumption you can change. The calculation sits right below, step by step.
Your numbers
Result
+144 hfreed per year
Assumptions and calculation
demi checks the parts in the product zone against your hygiene rules; you assess and release.
4 h → 2.8 h per case
How we calculate
10 assemblies × 4 h × 30% × 1.0 (manual) × 12 months = 144 h
Value per year, before demi costs
Freed per year+144 h
Assumption: labor cost of $48.62 per hour in US manufacturing in June 2026 (BLS), plus workplace, IT and overhead.
= Value per year, before demi costs
+$9,360
gained per year
144 h ÷ 1,760 h per role = 0.1 full-time roles
An estimate, not a promise. The starting values are assumptions for an industrial company with 150 to 500 people.
Combine with more cases and get the packageQuestions about this use case
How does demi know which surfaces touch the product?
From the zones in the model: food zone, splash zone and non-food zone, marked by color, layer or attribute. If they are missing, the agent proposes zones based on similar machines and the engineer confirms them once. From then on each zone has its own rules.
Which rules does the agent check against?
The rules you store: EN 1672-2, EN ISO 14159, your hygiene guideline and your customers' requirements, for example internal radii of at least 3 mm and roughness up to Ra 0.8 µm in the food zone. You set the limits per zone. Each finding names the rule it comes from.
Does demi also check bought-in parts?
Yes, if the supplier provides a 3D model. If there is only a data sheet, the agent reads the hygiene statements and certificates there and marks the geometry as unchecked. So you see where to ask the supplier.
Does it replace the cleaning test or the hygiene audit?
No. Certification, cleaning tests and the customer's audit stay as they are. demi makes sure known weak spots already show up in the model, and provides the check report per assembly.