Today
Many medical devices have been on the market for ten or fifteen years and were certified under the old directive. Under the MDR each one needs complete technical documentation, but the design history sits in paper binders, on drives of developers who have left and in systems replaced long ago. Nobody knows exactly what exists, what is missing and what no longer matches the state of the art, and the transition deadlines are running.
An example
Valbrecht has sold a syringe pump since 2008, still certified under the old directive. The agent assigns 2,140 documents from 38 scanned binders, the old DMS and two drives to the chapters of the MDR file. It shows 23 open points, among them a 2007 risk analysis without a benefit-risk assessment, test reports to the second edition of IEC 60601-1, missing software requirements and architecture documents for the current software version and two battery data sheets with different capacities. The head of regulatory affairs uses the list to plan retests and expert reports, and the file goes to the notified body only once every point is closed.
Your data, wherever it lives
The history of your legacy devices sits today in paper design binders, on drives of former employees, in the old DMS, in PLM and ERP and in test reports from external labs as PDFs. demi reads, understands and links them per product and chapter of the MDR file, with your rights. The AI shows in days instead of months what exists, what is outdated and what is missing, and regulatory affairs decides what is retested and submitted.
Where the data lives today
- Scans & paper
- Folders & drives
- DMS & archive
- QM system
- PLM
- Legacy systems
- ERP
- PDFs
How demi solves it
Three layers in this order: connect the data first, then the rights, then the AI.
- 1 · ConnectData Layer
Data sources in this case: scanned design and approval binders, network drives, the old DMS, PLM and ERP with BOMs and changes, and the QMS with complaints, CAPAs and test reports. demi replaces nothing and assigns every document to product, variant, version and chapter of the MDR file, with date, author and where it was found. Duplicate and conflicting versions are linked, not discarded.
- 2 · PermitPermission Layer
Design and approval documents are visible to regulatory affairs, quality management and the product's development team; personal data from complaints stay locked. What goes into the file is released by regulatory affairs through your controlled document process, with person and time in the log.
- 3 · ActIntelligence Layer
The agent checks the documents against the structure of Annexes II and III and against the general safety and performance requirements and shows the evidence or the gap for each requirement. It recognizes outdated editions of standards, missing software and usability documentation and contradictions between documents, each with its source. Whether evidence is sufficient it does not judge; your experts decide.
How it runs
- 1
Paper binders from development and approvals are scanned; drives, the old DMS, PLM, ERP and QMS are connected.
- 2
demi reads every document and assigns it to product, variant, version and chapter of the MDR file.
- 3
For each requirement the agent checks whether evidence exists and flags outdated editions of standards and contradictions.
- 4
Open points go as tasks to development, the test lab and quality management, each with its source.
- 5
Regulatory affairs releases the file through the controlled document process and submits it to the notified body.
What changes
A clear status for every legacy device: present, outdated, missing
Retests and expert reports planned early instead of just before the deadline
The design history stays findable, even after its authors have left
What does it bring you?
Check it with your own numbers
Every starting value is an assumption you can change. The calculation sits right below, step by step.
Your numbers
Result
+216 hfreed per year
Assumptions and calculation
demi gathers a product's documents and shows the gaps in the MDR file; you close them.
30 h → 21 h per case
How we calculate
2 product files × 30 h × 30% × 1.0 (manual) × 12 months = 216 h
Value per year, before demi costs
Freed per year+216 h
Assumption: labor cost of $48.62 per hour in US manufacturing in June 2026 (BLS), plus workplace, IT and overhead.
= Value per year, before demi costs
+$14,040
gained per year
216 h ÷ 1,760 h per role = 0.1 full-time roles
An estimate, not a promise. The starting values are assumptions for an industrial company with 150 to 500 people.
Combine with more cases and get the packageQuestions about this use case
How does demi measure what the file is missing?
Against the structure of Annexes II and III of the MDR, the general safety and performance requirements in Annex I and the standards you apply to the product. Each match shows the document and the passage; each gap shows what was searched for.
Does demi also read old paper files and retired systems?
Yes: scans of binders with stamps, signatures and handwritten notes, files from old drives and exports from systems that no longer run. Whatever the agent cannot read with certainty, it marks for review instead of skipping it.
Does demi create missing documents?
demi prepares drafts, such as the checklist of safety and performance requirements with references to the evidence or a summary of market data from complaints. Tests, clinical evaluation and signatures stay with your experts, and nothing is released automatically.
Does this replace the notified body's assessment?
No. demi shows status and gaps with their source. Whether evidence is sufficient is decided by regulatory affairs and, in the end, by the notified body; regulatory responsibility stays with you.